Search

Title Document Number
Sector Years
TC ICS

Catalogs

Oil of bitter orange petitgrain, cultivated (Citrus aurantium L.)

This International Standard specifies certain characteristics of the oil of cultivated bitter orange petitgrain (Citrus aurantium L.), in order to facilitate assessment of its quality. NOTE This Inte


Oil of lavandin Grosso (Lavandula angustifolia Mill. × Lavandula

This International Standard specifies certain characteristics of the essential oil of lavandin Grosso [Lavandula angustifolia Mill. × Lavandula latifolia Medik.], French type, intended for facilitatin


Shell boilers - Part 11: Acceptance tests

This Part of this European Standard specifies a concise procedure for conducting thermal performance tests, using The indirect (losses) procedure for boilers for steam or hot water. Test Results are b


Shell boilers - Part 12: Requirements for grate firing systems for

The Lebanese European Standard NL EN 12953 concerning shell boilers consists of the following Parts:  Part 1: General  Part 2: Materials for pressure parts of boilers and accessories  Part 3: De


Shell boilers - Part 13: Operating instructions

This European Standard identifies the requirements for the manufacturer to provide operating instructions for pressure equipment supplied in accordance with EN 12953-1 when placed on the market. NOTE


Standard for infant formula

تحدد هذه المواصفة القياسية المتطلبات والخصائص الواجب توافرها في المحضّرات الغذائيّة المعدّة للرضّع. كما تشمل طرق أخذ العينات والاختبار وشروط التعبئة والتخزين والنقل و التّوسيم التّغذوي. لا يسمح لأي


Plastics - Recycled plastics - Sampling procedures for testing

This Technical Specification specifies a system for sampling procedures for testing plastics waste and recyclates which take into account the specifics of the plastics waste and recyclates. It is inte


Plastics - Recycled plastics - Sample preparation

This Technical Specification specifies the preparation of samples of recycled plastics prior to testing and takes account of the specifics of the material. Sample preparation should avoid any process that causes 'de-mixing' of the sample. Following preparation, the sample should remain representative. The behaviour of contaminants should be carefully analysed and observed to ensure this is homogeneous. This Technical Specification does not address any legal or product safety issues.


Dentistry — Implants — Clinical performance of hand torque

This International Standard describes a classification system for hand-held torque wrenches intended for clinical use. It specifies their performance requirements in terms of accuracy and reproducibility and resistance to reprocessing. Test methods are described, and marking and labelling requirements are specified. This International Standard does not include electronically controlled devices.


Dentistry — Implants — Dynamic loading test for endosseous dental implants

This International Standard specifies a method of dynamic testing of single post endosseous dental implants of the transmucosal type in combination with their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. This International Standard is not a test of the fundamental fatigue properties of the materials from which the endosseous implants and prosthetic components are made. This International Standard is not applicable to dental implants with endosseous lengths shorter than 8 mm nor to magnetic attachments. While this International Standard simulates the functional loading of an endosseous dental implant under “worst case” conditions, it is not applicable for predicting the in vivo performance of an endosseous dental implant or dental prosthesis, particularly if multiple endosseous dental implants are used for a dental prosthesis.


Dentistry — Minimal dental implant data set for clinical use

This International Standard specifies the minimal data set to be recorded for a patient receiving dental implant treatment. This will comprise the locations and types of dental implant bodies, connecting components and adjunctive devices, including grafting materials, placed in a patient’s jaw(s). This information will be recorded by the responsible clinician in the patient’s file and should be made available to the patient by the clinician(s) who provided the care.


Dentistry — Designation system for dental implants

This International Standard provides a system for designating the location of an implant body within a jaw, and is intended for use with the scheme described in ISO 3950. It does not in itself indicate whether the device is visible within the oral cavity or the presence of transmucosal components or implant restorations. Since the system describes location but not restoration form, it is not necessary to use the quadrant designation numbers 5 to 8 which are employed when indicating a primary tooth. This information should be recorded by the responsible clinician in the patient’s file and made available to the patient by the clinician(s) who provided the care.


Dentistry — Implantable materials for bone filling and

This International Standard applies to implantable materials, whether resorbable or non-resorbable, used as dental devices for filling and augmenting bones in oral and maxillofacial surgery. Products that are essentially pure (> 90 %) hydroxyapatite are not covered by this International Standard. Evaluation includes the physico-chemical, mechanical, biological and clinical aspects and behaviour of these implantable dental materials. Materials such as autografts, allografts and membranes, and products for which the primary intended use is to deliver a medicinal product, are not covered by this International Standard.


Dentistry — Membrane materials for guided tissue

This International Standard gives the requirements for a technical file on the evaluation of the chemical, physical, mechanical, biological and clinical aspects and behaviour of membrane materials, whether resorbable, partially resorbable or non-resorbable, which are used — for guided tissue regeneration in oral and maxillofacial surgery to correct a morphological defect or abnormality, — in contact with teeth and/or dental implants, — for prevention of epithelial migration in periodontal surgery, — for the augmentation of bone prior to the planned insertion of dental implants, — and/or for augmentation of bone for stabilization of dental prostheses. This International Standard is not applicable to materials whose primary intended use is to deliver a medicinalproduct, autografts and allografts, or materials intended to act through pharmacological, immunological ormetabolic means.


Permanently installed Lifts (Elevators) in buildings –Principles, requirements and guidelines

This document gives guidelines on the implementation of the Lebanese standards related to passenger lifts, passenger and goods passenger lifts and goods only lifts, permanently installed in buildings. This document covers: — Planning, selection, construction, installation, verification of new lifts with or without passengers in new or existing buildings — Risk assessment and maintenance requirement of existing lifts in buildings with or without passengers. — Planning requirement and dimension selection for special type of lift usage: lifts for persons with disability, vehicle lifts and private lifts This document is not applicable to: — Automated Parking systems — Builders hoists — Escalators and moving walks — Cranes and suspended access equipment — Mining lifts — Stage lifts


Maintenance for lifts and escalators - Rules for maintenance

This European Standard specifies the elements necessary for the preparation of the instructions for the maintenance operations, as in 3.1, which are provided for new installed passenger lifts, goods passenger lifts, accessible goods only lifts, service lifts, escalators and passenger conveyors. This European Standard does not cover: a) instructions for the installation and the dismantling; b) any legal examinations and tests based on national regulations. Existing installations are not covered by this Standard, but it can be taken as a reference.


Oil of bitter orange petitgrain, cultivated (Citrus aurantium L.)

This International Standard specifies certain characteristics of the oil of cultivated bitter orange petitgrain (Citrus aurantium L.), in order to facilitate assessment of its quality. NOTE This International Standard is not applicable to the oil of petitgrain, Paraguayan type, described in ISO 3064.


Escalators -- Building dimensions

This International Standard specifies the building dimensions for the space needed to install escalators, as shown in figure 1. - certain escalators which are subject to special operational conditions, for which other design dimensions may be required (mainly in public traffic systems); It applies to escalators with a maximum nominal speed of 0,5 m/s, an inclination angle of 30” or 35” and a rise from 2 m to 6 m. The machine room is a part of the truss. - special designs like spiral escalators, combinations of escalators and passenger conveyors, etc.


Definition of steel products

This European Standard defines terms for steel products according to: a) shape and dimensions; and b) appearance and surface condition. NOTE 1 Although the products are generally defined independently of their end uses or manufacturing processes, it has sometimes been necessary to make reference to these criteria. NOTE 2 All dimensions given in this European Standard are nominal.


Designation systems for steels - Part 1: Steel names

1.1 This European Standard specifies rules for designating steels by means of symbolic letters and numbers to express application and principal characteristics, e.g. mechanical, physical, chemical, so as to provide an abbreviated identification of steels. NOTE In the English language the designations covered by this European Standard are known as “steel names”; in the French language as “designation symbolique”; in the German language as “Kurznamen”. 1.2 This European Standard applies to steels specified in European Standards (EN), Technical Specifications (TS), Technical Reports (TR) and CEN member's national standards. 1.3 These rules may be applied to non-standardized steels. 1.4 A system of numerical designation of steels known as steel numbers is specified in EN 10027-2.


Designation systems for steels - Part 2: Numerical system

1.1 This European Standard specifies a numbering system, referred to as steel numbers, for the designation of steel grades. It deals with the structure of steel numbers and the organization for their registration, allocation and dissemination. Such steel numbers are complementary to steel names set out in EN 10027-1. This European Standard is applicable to steels specified in European Standards. This European Standard may be applied to national steels and proprietary steels. NOTE Although the scope of the systems is limited to steel, it is structured so as to be capable of being extended to include other industrially produced materials. 1.2 Steel numbers established in accordance with this system have a fixed number of digits (see Clause 5). They are better suited for data processing than steel names established in accordance with EN 10027-1. 1.3 For steels specified in European Standards the application for allocation of steel numbers (see A.6 to A.9) is the responsibility of the


القضبان الفولاذية المستديرة المدرفلة على الساخن للاستعمالات العامة -

This European Standard specifies the nominal dimensions and the tolerances on dimensions and shape of hot-rolled round steel bars.


Hot rolled spring steel flat bars - Part 1: Flat bars – Dimensions

This Part of this European Standard specifies the nominal dimensions and the tolerances on dimensions and shapes of hot rolled steel flat bars for springs with three different types of profiles (A, B, and C). Formulas for calculation the moment of inertia are specified in annex A. This standard is applicable only to spring steel flat bars produced from steel grades specified in EN 10089.


Hot rolled taper flange I sections - Tolerances on shape and

This European Standard specifies requirements for tolerances on dimensions, shape, and mass of hot rolled taper flange "I" Sections. These requirements do not apply to taper flange "I" Sections produced from stainless steel.


Continuously hot rolled low carbon steel sheet and strip for cold

This European Standard specifies the grades of continuously hot rolled low carbon steel sheet and strip (in coils) for cold forming. Depending on its actual width, strip is classified as:  hot rolled wide strip if its width is greater than or equal to 600 mm;  hot rolled slit wide strip if its width is less than 600 mm. For each grade, it specifies the chemical composition and the mechanical properties. This European Standard is applicable to products of thickness not less than 1,0 mm and not exceeding 11 mm. This European Standard is not applicable to products covered by other standards, such as:  hot rolled products of non-alloy structural steels for general use (see EN 10025 all parts);  steel sheet for pressure purposes (see EN 10028 all parts);  steel sheet for welded gas cylinders (see EN 10120);  quenched and tempered steels (see EN 10083-1 and EN 10083-2).


Fans -- Vocabulary and definitions of categories

This International Standard defines terms and categories in the field of fans used for all purposes. It is not applicable to electrical safety.


Fans -- Dimensions

This International Standard specifies the dimensions of the circular and rectangular flanges of general-purpose fans, as well as the fan size designations. It is not applicable to cross-flow fans or to fan appliances used for individual household or similar applications. For circular flanges, it provides for three different flange series: one for light-duty casing thicknesses, another for medium-duty fans and the third for heavy-duty fans as used on sea-going vessels or in heavy industry. In order not to restrict fan design unduly, only the pitch diameter, hole numbers and hole diameters are specified. Flange thickness, as well as internal and external flange diameters, may be chosen freely within the limits of good engineering practice.


Heat pumps with electrically driven compressors - Testing, performance rating and requirements for m

This European Standard specifies methods for testing, rating of performance and calculation of water heating energy efficiency of air/water, brine/water, water/water and direct exchange/water heat pump water heaters and heat pump combination heaters with electrically driven compressors and connected to or including a domestic hot water storage tank for domestic hot water production. This European Standard comprises only the testing procedure for the domestic hot water production of the heat pump system. NOTE 1 Testing procedures for simultaneous operation for domestic hot water production and space heating are not treated in this standard. Simultaneous means that domestic hot water production and space heating generation occur at the same time and may interact. NOTE 2 For heat pump combination heaters the seasonal efficiency of space heating is determined according to EN 14825. This European Standard only applies to water heaters which are supplied in a package of heat pump and sto


Cranes other than mobile and floating cranes -- General

This International Standard specifies the conditions to be met when verifying, by calculation, the stability of all crane types defined in ISO 4306-1 that are subject to tipping (except mobile cranes and floating cranes); it assumes that they are standingon a firm, level supporting surface or track. The sliding of cranes on their tracks is not covered by this International Standard.


Cranes -- Inspections -- Part 5: Bridge and gantry cranes, including portal and semi-portal cranes a

This document specifies the inspections to be carried out on bridge and gantry cranes. It is intended to be used in conjunction with ISO 9927-1. It does not cover inspection prior to the first use of a bridge or gantry crane.


Cranes — Requirements for mechanisms — Part 1: General

This part of ISO 10972 establishes requirements which apply generally to mechanisms and related components of cranes and lifting appliances as described in ISO 4306-1, ISO 4306-2 and ISO 4306-3. Requirements concern: a) general layout and design of mechanisms; b) selection and/or design requirements of components; c) instructions for manufacture, mounting, installation and testing. Rules for proof of competence calculation regarding different limit states (yield strength, fatigue, wear) are excluded from this part of ISO 10972.


Cranes — Requirements for mechanisms — Part 2: Mobile cranes

This part of ISO 10972 establishes requirements specific to the mechanisms of mobile cranes, in addition to the general requirements for cranes given in ISO 10972-1. These additional requirements concern a) the arrangement, features and characteristics of the crane mechanisms, and b) the minimum requirements for certain mechanism components. Rules for the proof of competence calculation regarding different limit states (yield strength, fatigue, wear) are excluded from this part of ISO 10972.


Cranes — Requirements for mechanisms — Part 3: Tower cranes

This part of ISO 10972 establishes requirements which apply specifically to the mechanisms and related components of tower cranes, in addition to the general requirements given in ISO 10972-1. These additional requirements concern a) the arrangement, features and characteristics of the crane mechanisms, and b) the minimum requirements for certain mechanism components. Rules for the proof of competence calculation regarding different limit states (yield strength, fatigue, wear) are excluded from this part of ISO 10972. This part of ISO 10972 is not applicable to the climbing mechanisms and related components used on tower cranes, nor to the climbing frame.


Cranes — Requirements for mechanisms — Part 4: Jib cranes

This part of ISO 10972 establishes the particular requirements relating to mechanisms for jib cranes as defined in ISO 4306-1. The general requirements for mechanisms for cranes are given in ISO 10972-1. These particular requirements concern a) general layout and design of mechanisms, b) selection and/or design requirements of components, and c) instructions for manufacture, mounting, installation and testing. Rules for proof of competence calculation regarding different limit states (yield strength, fatigue, wear) are excluded from this part of ISO 10972.


Cranes — Requirements for mechanisms — Part 5: Bridge and

This part of ISO 10972 establishes the particular requirements relating to mechanisms for bridge and gantry cranes, as defined in ISO 4306-1. The general requirements for mechanisms for cranes are given in ISO 10972-1. These particular requirements concern a) the general layout and design of mechanisms; b) the selection and/or design requirements of components; c) the instructions for manufacturing, mounting, installation and testing. Rules for proof of competence calculations regarding different limit states (yield strength, fatigue, wear) are excluded from this part of ISO 10972.


Cranes — Stiffness — Bridge and gantry cranes

This International Standard gives recommendations and requirements for the stiffness properties of the structures for bridge and gantry cranes in terms of deflections and natural frequencies.


Plastics - Recycled plastics - Determination of selected marker compounds in food grade recycled pol

polyethylene terephthalate (PET). This analytical method provides / is intended to be used as a quality control check. This test identifies and quantifies certain specified contaminants. Such contaminants are referred to as Marker Compounds. The analytical method is applicable for use on PET samples and products at all stages in the recycling process and will therefore be useful to recycling companies producing commercial, recycled PET for food contact materials and articles, and the manufacturers of such articles. This Technical Specification is without prejudice to any existing legislation. NOTE Marker compounds are known to originate from two sources: — from the PET material itself (i.e. residual monomers, degradation products or reaction/breakdown products); — from food products that the PET has contacted during its “first use”. WARNING – The use of this Technical Specification might involve hazardous materials, operations and equipment. Persons using this Technical Specific


Plastics — Post-consumer poly(ethylene terephthalate) (PET)

1.1 This part of ISO 12418 establishes a designation system for post-consumer poly(ethylene terephthalate) (PET) bottle recyclates, which may be used as the basis for specifications. 1.2 The types of PET bottle recyclate are differentiated from each other by a classification system based on appropriate levels of the following designatory properties: a) intrinsic viscosity (IV); b) levels of contamination due to the label and other visible contaminants, PVC and polyolefins (and including adhesive); c) water content; d) bulk density. Information regarding the intended application or method of processing will also assist in classification. 1.3 This part of ISO 12418 is applicable to all PET bottle recyclates. It applies to materials ready for normal use in the form of powder, flakes or pellets. 1.4 It is not intended to imply that materials having the same designation will give the same performance. This part of ISO 12418 does not provide engineering data or data on processin


Plastics — Post-consumer poly(ethylene terephthalate) (PET)

This part of ISO 12418 specifies the test methods to be used in determining the properties of post-consumer poly(ethylene terephthalate) (PET) bottle recyclates.


Plastics — Mixtures of polypropylene (PP) and polyethylene

This part of ISO 18263 establishes a system which can be used as the basis for specifications for mixtures of polypropylene (PP) and polyethylene (PE) recyclate. It covers mixtures of polypropylene (PP) and polyethylene (PE) recyclate derived from PP and PE used for flexible and rigid consumer packaging for moulding and extrusion. Recyclate from packaging used for the transport, handling, or storage of hazardous goods shall not be used. It does not apply to mixtures of recyclates and virgin resin. It does not apply to the mixtures containing special type of PE or PP, for example, PE-UHMW, TPO, etc. The types of mixtures of PP and PE recyclate are differentiated from each other by a classification system based on appropriate levels of the designatory properties. a) Composition b) Melt mass-flow rate c) Density d) Colour It is not intended to imply that materials having the same designation give necessarily the same performance. This part of ISO 18263 does not provide engin


Plastics — Mixtures of polypropylene (PP) and polyethylene

This part of ISO 18263 specifies methods of preparation of test specimens and the standard test methods to be used in determining the properties of mixtures of polypropylene (PP) and polyethylene (PE) recyclate derived from PP and PE used for flexible and rigid consumer packaging for moulding and extrusion. Recyclate from packaging used for the transport, handling, or storage of hazardous goods is not to be used. Since it is impossible to get the information about stabilizer levels of recyclate, it is necessary to add stabilizer as needed. Requirements for handling test material and for conditioning both the test material before moulding and the specimens before testing are given in this part of ISO 18263


Wind Action on Buildings

(1) The present Standard gives rules and methods of calculation for loads of wind exercised on buildings of height lower than 200 ms, their components and their appendixes. (2) Loads of wind must be calculated for each of zones affected by these actions: - the whole of the structure; - or a part of the structure, that is some of his/her/its elements, shifting boards and their fixings. (3) The present Standard also gives rules for chimneys and other recessed structures in foot. The relative special conditions to towers in lattice don't appear there.


Foods for special dietary use for persons intolerant to gluten

تطبق هذه المواصفة القياسية على الأغذية المصنعة والمحضرة خصيصاً كي تلائم احتياجات الحمية للأشخاص الذين يعانون عدم تحمل الغلوتين. كما تشير هذه المواصفة حصراً الى التدابير الخاصة المتعلقة بالغرض التغذوي المحدد الذي ترمي اليه هذه الأغذية. ولا تطبق هذه المواصفة على الأغذية الخلوة أصلاً وبشكلها الطبيعي من الغلوتين.


Natural stone products - Modular tiles - Requirements

This European Standard specifies requirements for flat modular tiles of natural stone which are made for internal (including enclosed public transport premises) and/or external uses as floorings, stairs and wall and ceiling finishes. This European Standard does not cover mineral aggregates and artificial agglomerated stone material and does not cover installation.


Essential oil of oregano [Origanum vulgare L. subsp. hirtum (Link) letsw]

This European Standard specifies the requirements for factory made wood fibre products, with or without facings or coatings, which are used for the thermal insulation of buildings1. The products are manufactured in the form of rolls, batts, felts, boards or slabs. This European Standard specifies product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,50 m2⋅K/W or a declared thermal conductivity greater than 0,070 W/(m⋅K) at 10 °C are not covered by this European Standard. This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.


Surface active agents -- Simplified classification

The simplified system enables the characteristics of the substances to be expressed by an abbreviated lettering and numbering system, consisting of one letter and four figures (five in the case of compounds comprising several hydrphilic groups). The letter designates the ionic character and figures correspond to the functional groups present in the molecule.


Soaps and detergents -- Techniques of sampling during manufacture

A certain number of increments is taken from the batch to be sampled. The increments are mixed to form a representative sample (bulk sample). From the representative sample a final sample is prepared by means of replicate reductions.


Surface active agents and detergents -- Methods of sample division

A bulk sample is reduced by a mechanical process until a reduced sample is obtained. The reduced sample may be used for the following purposes: a) the preparation of a final sample or a laboratory sample of mass greater than 250 g from a blended bulk sample of mass greater than 500 g; b) the preparation of several equivalent laboratory samples and/or reference samples and/or storage samples, each of a mass greater than 250 g, from a final sample; c) the preparation of a test sample from a loboratory sample.


Ductile iron pipes, fittings, accessories and their joints for sewerage applications - Requirements and test methods

This European Standard specifies the requirements and associated test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings:  operating without pressure (gravity sewerage), or with positive or negative pressure (see Table 5);  to be installed below or above ground;  to convey surface water, domestic waste water and certain types of industrial effluents, either in separate systems or in combined systems. This European Standard applies to pipes, fittings and accessories which are:  manufactured with socketed, flanged or spigot ends;  normally delivered externally and internally coated;  suitable for continuous fluid temperatures between 0 °C excluding frost, and 45 °C for DN ≤ 200 or 35 °C for DN > 200, according to EN 476;  not intended for use in areas subject to reaction to fire regulations. NOTE 1 This does not preclude special arrangements for the products to be used at higher temperatures.


Ductile iron pipes, fittings, accessories and their joints compatible with plastic (PVC or PE) piping systems, for water applications and for plastic pipeline connections, repair and replacement

This International Standard specifies the requirements and test methods applicable to ductile iron pipes, fittings, accessories and their joints with dimensions compatible with plastic (PVC or PE) piping systems: — to replace or repair existing plastic pipelines; — to convey water (e.g. for human consumption, raw water, etc.); — operated with or without pressure; — installed below or above ground; — defined according to their external diameter (DN/OD series); — classified according to pressure (C class). The pressure class specified in this International Standard is C25. This pressure resistance level will meet or exceed those of plastic pipes. These ductile iron pipes, fittings, accessories and joints can be used along with plastic pipelines, where they are needed (for example, with higher pressure rating sections, higher traffic load, etc.), for the construction of water pipelines. The dimensions of the products according to this International Standard, in the size range DN/OD 50 to DN/OD 225, are compatible with those of plastic pipes (ISO 1452-2 for PVC and ISO 4427-2 for PE). The spigots of plastic pipes used for water applications can be inserted into sockets of pipes manufactured according to this International Standard. The spigots and sockets of products defined in this International Standard are not dimensionally compatible with the products defined in ISO 2531. This International Standard gives specifications for materials, dimensions and tolerances, mechanical properties and standard coatings and linings of pipes, fittings and accessories. It also gives performance requirements for all components including joints. This International Standard covers pipes, fittings and accessories cast by any type of foundry process or manufactured by fabrication of cast components, as well as corresponding joints in the size range DN/OD 50 to DN/OD 225 inclusive. It is applicable to pipes, fittings and accessories which are — manufactured with socketed or spigot ends for jointing by means of various types of gaskets (which are not within the scope of this International Standard), and — compulsory delivered internally and externally coated. This International Standard is also applicable to socketed fittings which include flanged connections. NOTE In this International Standard, all pressures are relative pressures expressed in bar1).